Drivon

DV

Drivon

  • D063FRENOT080B14_CAM1
  • D063FRENOT080B14_CAM2
  • D063SERVT080B34_CAM1
  • D063SERVT080B34_CAM2
  • D063T080TASTB34_CAM1
  • D063T080TASTB34_CAM2
  • D063T080TB14_CAM1
  • D063T080TB14_CAM2
  • D100T112B35_CAM1
  • D100T112B35_CAM2
  • D100T112TAST_CAM1
  • D100T112TAST_CAM2
  • D06300TAST_CAM1
  • D06300TAST_CAM2
  • D06330FILO
  • D06360M1
  • D06360M2
  • D06360M3
  • D06360M4

                              

DRIVON, designed to be used in different types of applications (especially pumps, fans and conveyor belts) consists of extremely reliable components and is controlled by our software that provides excellent performance with special attention to the system energy efficiency. Its Vectorial Check, besides ensuring a constant motor torque throughout a wide range of frequencies without requiring the use of the servo-ventilation at low rpm, provides fast and precise output according to the application dynamic conditions allowing high torque overload of the motor.

Conceived for extremely different and variable supply conditions, Drivon is available both in single-phase/three-phase version (200 ÷260 V / 47 ÷ 63 Hz) with a motor power between 0.25 and 1.5 kW, and in three-phase version (360 ÷ 480 V / 47 ÷ 63 Hz) with a motor power between 0.25 and 5.5 kW.

The different functions of this software provide a wide range of standard and optional interfaces for a simple and flexible use.

The electronic part, available in 10 power sizes, is located in two different chassis sizes, one for power up to 1.5 kW and the other for power up to 5.5 kW.

Certifications Available: UL/CSA

Warranty: Two years from delivery date

                  

Characteristics
Range
Downloads
PRODUCT CHECK LIST
Request more info

230 V Drivon:

  • Single-phase and three-phase power supply: (200÷260) V / (47÷63) Hz
  • Rated power: 0.25; 0.37; 0.55; 0.75; 1.1; 1.5 kW
  • Speed range: 0÷2500 rpm

400V Drivon:

  • Three-phase power supply: (360÷480) V / (47÷63) Hz
  • Rated power: 0.25; 0.37; 0.55; 0.75; 1.1; 1.5; 2.2; 3.0; 4.0; 5.5 kW
  • Speed range: 0÷3000 rpm

General functions:

  • FOC open-loop vectorial control of asynchronous motors
  • Protection class: IP55 (IP56, IP65, IP66 optional)
  • Built-in STO (Safe Torque Off) feature for safe stop according to ISO 13849-1 and IEC 61508 standards
  • On-board potentiometer with Start function featuring programmable threshold
  • Built-in USB interface
  • Integrated CANopen DSP402 and Modbus RTU field Bus
  • Continuous duty at low speed with reduced use of servo-ventilation
  • Torque overload of 200% at transient rpm
  • Motor I2t thermal cut-out
  • PTC and bimetallic thermal probe input
  • Multi-colour status LED for quick diagnosis
  • Programmable multifunction opto-isolated digital inputs
  • Maximum drive torque can be set by the user
  • Possible speed setting by means of the encoder on motor
  • Enable auto search for idling motor speed at starting
  • Combinatorial multiple frequency reference
  • Dynamic braking with emergency fast stop
  • External process PI regulator with analogue feedback
  • S-ramps with programmable parameters
  • Mechanical resonance frequency controlled management
  • Control and programming smart keypad (optional)
  • Potentiometer + movement direction control module (optional)
  • Profibus DP communication module (optional)
  • Electro-mechanic braking module (optional)
  • I/O expansion module (optional)
  • Dynamic braking module with integrated resistor (optional)

SMART KEYPAD (optional):

  • Integrated in the inverter or remote-type
  • Mechanical fixing with possibility to set its orientation
  • Remote control by means of a cable and RJ connection
  • Parameter setting and Control functions
  • 7-segment 4-digit display
  • UP/DOWN/ENTER/MODE/FWD_REV buttons
  • Parameter Copy function
  • JOG function

To enable us to identify the correct product for your requirements please complete the below form.
Required field
Required field
CUSTOMER INFO
  • Required field
  • Required field
  • Required field
  • Required field
  • Required field
  • Required field
GENERAL INFO OF THE APPLICATION
Environment:(tick one choice)

Field of application:
Required field

Type of drive:
Required field

Description of the drive:
Required field
PRELIMINARY INFORMATION
Do you want to replace a mechanical variator with DRIVON?

Do you want to replace a frequency inverter with DRIVON?
If YES:


Do you want to replace an inverter motor with DRIVON?
If YES:


Is there a mechanical reducer assembled to DRIVON?
ENVIRONMENT CONDITIONS

Humidity:

Corrosive materials:

Volatile dust:

Vibration:
GENERAL INFORMATION ON THE PLANT
Is it present an automatic differential switch?

Is it present an automatic magneto-thermal switch?

Is it present a network filter?

Are there other inverters supplied from the same plant?

Which is the maximum expected length of the electric cable that supply the motoinverter?
Required field

Power supply network of the application

Max possible voltage in the 24h:

Min possible voltage in the 24h:

Frequency:
TYPE OF CONTROL OF THE INVERTER
Manual, by an operator:

Industrial PC:

PLC:

CNC:

Other inverter:

Other device:
APPLICATION INFO
AMax speed required
min-1

AMin speed required
min-1

APower required at max speed (Pb)
kW

APower required at min speed (Pa)
kW

BStarting torque required at the motor shaft (Ms)
Nm

CMin time of acceleration (Tavv)
sec

CMin time of deceleration (Tarr)
sec

Type of duty of the motor (tick one choice):

(1) The motor performs a S1 service if, once started, it remains in movement without any stops.

(2) The motor performs a S2 service if, once started, it remains in movement for a limited time (20-30 minutes) before a stop of 2-3 hours.

(3) The motor performs a S3 service if it is subject to iterative cycles of starts and stops for a short time (maximum 2-3 minutes).


In case of limited duration duty (S2), how long is the movement?
Min

In case of intermittent duty (S3, S4, ...), how long is the movement phase?
sec

In case of intermittent duty (S3, S4, ...), how long is the stop phase?
sec

In case of intermittent duty (S3, S4, ...), which is the duty cycle?
sec
PRECISION REQUESTED FOR THE VARIATION
Speed tolerance
%

Torque tolerance
%

MODE TO SELECT THE SPEED
Potentiometer on board:
Moto-potentiometer

Remote potentiometer:
Binary combination of digital inputs

Keyboard on board:
Square waveform with frequency modulation

Remote Keyboard:
Modbus RTU

Analog signal

CANOpen DSP402
INVERTER FUNCTIONS
Start/Stop:

Change the direction of rotation:

Speed reference:

Other:
FIELDBUS
Modbus RTU:
CANOpen DSP402:

Others:
Tools for Programming the inverter
PC configuration:
Modbus:

Smart Keybord:
CANOpen:

Other:
OTHER REQUIREMENTS OF THE MOTOINVERTER
Protection degree IP:
Contact us
Required field
Required field
Required field
Required field
Required field
Required field
Required field